Welcome to our Know-How section
-a place for engineers, students, researchers, and technically curious readers to explore practical knowledge around laser measurement systems and precision optics.
With over 30 years as a manufacturer and supplier, we work with these technologies daily, and here we share that experience in a clear, useful way. Over time, this page will grow into a collection of articles, explanations, and application notes — from fundamentals to specific measurement principles, optical components, and real-world application challenges.
Whether you’re researching a project, comparing technologies, or simply curious about what’s possible, this section is here to help you learn and make informed decisions.
Table of Contents

Birefringent Materials for Polarization Optics
A Technical Guide Table of Contents Polarization By polarized light we mean optical radiation whose electric field oscillates in a specific, regular manner. Every ordinarily polarized electric field can be decomposed into two orthogonally polarized components. If the light is linearly polarized, the electric field oscillates in a single plane — the plane of polarization — and the two components are in phase with one another. If the light is elliptically polarized, the components have a constant phase difference, and the tip of the electric field vector follows a three-dimensional ellipse as the beam propagates. Circularly polarized light is a

Gated Integrators and Boxcar Averaging for Time-Resolved Signal Detection
Table of Contents Gated Integrators and Boxcar Averaging for Time-Resolved Signal Detection Precise measurement of weak transient signals is a common challenge in optical and photonics research. Many experiments generate signals that exist only briefly following a trigger event, such as a pulsed laser excitation. In these cases, conventional measurement methods often struggle to distinguish the desired signal from background noise or ambient light. Gated integrators and boxcar averagers provide an effective solution to this problem by allowing measurements to be performed only within a precisely defined time window. Instruments such as the GIA100, a gated integrator and boxcar averager,

Positional Dependence of Detector Sensitivity
The sensitivity of a large area photodiode detector at a given wavelength is dependent on various factors such as beam size, angle of incidence and the position on the active area illuminated by the laser beam. The positional dependence is mainly due to etalon effects in the protection window of the photodiode. This dependence can be minimized by covering the photodiode with a suitable diffusing material, as is the case for most large area photodiode detectors from Artifex Engineering. This has the effect of homogenizing the beam to some extent. A typical positional dependence is shown in the following diagram

TZA- Best Methods for Noise Suppression
Introduction The TZA500 from Artifex Engineering is a precision transimpedance amplifier (TZA or TIA) used to convert very small currents (pA–mA) from sensors such as photodiodes or PMTs into measurable voltages. Because these measurements often occur at extremely low signal levels, noise suppression may be critical for obtaining accurate results. Below is a detailed explanation of the TZA- Best Methods for Noise Suppressionavailable when using the TZA500, including inherent design, instrument-based techniques and experimental setup methods. Table of Contents Noise Rejection by Design Electromagnetic Interference (EMI) The TZA series amplifiers are designed to be largely insensitive to electromagnetic interference, which

Transimpedance Amplifiers for Photodiodes
Theory, Design and Applications Introduction Photodiodes are widely used to detect light in photonics experiments, spectroscopy systems and optical sensing applications. However, the electrical signals generated by photodiodes are typically extremely small—often in the nanoampere or picoampere range with a maximum of a few milliamperes. Measuring such weak signals requires specialized electronics capable of converting tiny currents into usable voltage signals. A transimpedance amplifier (TZA or TIA) is the most common circuit used for this purpose. By converting photodiode current directly into a proportional voltage, a transimpedance amplifier enables accurate detection of very weak optical signals. This article explains how

Laser Power Measurement Using Photodiode-Based Power Meters
A Practical Tutorial Introduction Laser power measurement is one of the most fundamental tasks in photonics research, laser development, and optical system testing. Whether evaluating a laser diode, characterizing an LED, or calibrating an optical instrument, accurately determining the amount of emitted light is essential for reliable performance and reproducible experiments. Applications include laboratory experiments, industrial laser processing, telecommunications and optical system alignment. One of the most common instruments used for this purpose is a photodiode-based power meter. These devices are valued for their fast response, high sensitivity, compact size and relatively low cost. A photodiode power meter converts incident

Eliminating Ambient Light When Using the OPM150 Laser Power Detector
Introduction Laser power detectors (photodiode-based detectors) can be affected by ambient light sources such as laboratory lighting, sunlight, or reflections from surrounding optics. Since photodiodes detect all incident photons within their spectral response, these unwanted sources contribute to the measured signal leading to erroneous results. The OPM150 Optical Power Meter uses calibrated photodiode detector heads covering wavelength ranges from 250 nm to 2490 nm depending on the detector type, allowing accurate measurements of visible and infrared lasers. To ensure accurate results in the presence of ambient light, calibrated optical filters (e.g., spectral filters) can be used to attenuate unwanted light

Calibration of Photodiode-Based Laser Power Meters
A Complete Guide Introduction Photodiode-based laser power meters are widely used in research, industrial processing, telecommunications and medical applications due to their fast response times, high sensitivity and compact design. However, to ensure accurate and reliable measurements, regular calibration is essential. Improper calibration can lead to measurement errors, reduced process quality and even safety risks. This article provides a comprehensive guide to the calibration of photodiode-based laser power meters, covering principles, methods, standards and best practices. Table of Contents What Is a Photodiode-Based Laser Power Meter? A photodiode-based laser power meter uses a semiconductor photodiode to convert incident laser light

Laser Diode LIV Characterization Explained
Introduction Laser diodes are among the most widely used optical sources in modern photonics. They are found in applications ranging from optical communication and spectroscopy to medical devices and industrial sensing as well as cutting and welding with high power lasers in manufacturing environments. To evaluate their performance and reliability, engineers rely on a standardized testing method known as LIV characterization. LIV measurements analyze the relationship between light output (L), electrical current (I) and voltage (V) of a laser diode. By measuring these three parameters simultaneously, researchers can determine key performance characteristics such as threshold current, efficiency and optical output

Integrating Sphere Theory and Applications
Introduction Many optical sources emit light in multiple directions rather than in a narrow beam. Measuring the total power from these sources can be challenging because conventional detectors capture only a portion of the emitted light. An integrating sphere solves this problem by collecting and redistributing light inside a highly reflective spherical cavity. This allows detectors to measure the total optical power emitted by a light source regardless of beam direction or spatial distribution. Integrating spheres are widely used in photonics laboratories for measuring lasers, LEDs, optical sensors and other light sources. Table of Contents What Is an Integrating Sphere?

Gated Integrator vs Lock-In Amplifier
Selecting the Right Instrument for Optical Measurements Abstract Accurate detection of weak signals is a fundamental challenge in photonics and optical research. Two common techniques—gated integration with boxcar averaging and lock-in amplification—offer complementary solutions. This article examines the operational principles of each method, compares their applications, and provides guidance for selecting the appropriate instrument based on experimental requirements. Introduction Laboratory experiments in laser spectroscopy, photoluminescence, and time-resolved optical measurements frequently involve signals that are transient, low in amplitude, and susceptible to interference. Selecting the correct measurement technique is critical for obtaining reliable results. Gated integrators and lock-in amplifiers are both

Detecting Weak Optical Signals from Photodiodes
Abstract Photodiodes are essential detectors in optical and photonics research due to their fast response and linearity. Detecting extremely weak optical signals from photodiodes presents challenges, including electronic noise, ambient light interference, and low signal amplitude. This article outlines professional approaches for measuring weak photodiode signals, with a focus on gated integration, boxcar averaging, and supporting instrumentation. Introduction Weak optical signals, often in the sub-nanoampere range, are common in laser spectroscopy, photoluminescence, and time-resolved experiments. Standard measurement techniques frequently struggle to resolve these signals from noise. By leveraging gated integration and boxcar averaging, researchers can achieve accurate and reproducible measurements,