- High power handling: up to 5kW (CW)
- High power density: 5kW/cm²
- Compatibility: OPM150 or OPM500 power meters via fibre coupling
The G100L is a liquid-cooled, gold-coated integrating sphere from Artifex Engineering with a 100 mm inner diameter, designed to measure high power lasers up to 5 kW (CW) at a power density of 5 kW/cm² across a wavelength range of 650 nm to 20 µm. Combined with a photodiode-based Artifex optical power meter, the G100L captures power fluctuations on a microsecond time scale – something conventional thermopile detectors simply cannot do.
- Sphere inner diameter: 100mm
- Input port diameter: 25mm
- SMA or FC fibre ports
- Standard 2 port design (eg: power and spectrometer); 4 ports on request
- Power density: 5000W/cm²
- Wavelength range: 650nm – 20µm
High power laser measurements are traditionally performed with thermopile detectors. Thermopiles, however, react slowly: typical rise times result in measurement periods of one second at best. The gold integrating sphere changes that. Paired with a photodiode-based power meter, it opens the door to measuring high power fluctuations in the µs range, making it an essential tool for setting up, optimizing and debugging high power CW lasers.
The inner gold coating is a highly reflective diffuse material optimized for the infrared, giving the G100 outstanding performance in the near infrared (NIR) and mid infrared (MIR). Active liquid cooling keeps the sphere stable even under extreme continuous load.
Applications
The G100 is built for demanding high power laser environments, including industrial CW laser setup and debugging, real-time monitoring of laser power stability, simultaneous power and spectral analysis using the multi-port design, and NIR/MIR laser characterization in research and production.
Options and Accessories
Choose between SMA or FC fibre ports and a 2- or 4-port configuration. Artifex also offers dedicated FC and SMA adapters for the G100L, which use a proprietary design to eliminate back reflections into the detector that would otherwise cause miscalibration. A 500 W chiller (20.208.00054) is available as an accessory.
Plug In and Start Measuring
Connect the G100L via fibre to an OPM150 or OPM500 optical power meter, plug it into your USB port and start measuring. Every Artifex device includes the free Software Development Kit with VB.net source code, a LabVIEW VI and full command documentation.
Customized Solutions
Need a different port configuration, an aperture limiter or a recalibration? Artifex Engineering is ISO 9001:2015 and ISO 14001:2015 certified and builds customized integrating sphere solutions to fit your exact requirements. Contact our team for a personal consultation and quote.
- Ports: SMA or FC fibre
- Number of ports: 2 or 4
500W Chiller 20.208.00054
| wdt_ID | wdt_created_by | wdt_created_at | wdt_last_edited_by | wdt_last_edited_at | Photo | Name | Description | Connector | Compatibility | Link |
|---|---|---|---|---|---|---|---|---|---|---|
| 11 | benjamin | 08/06/2026 01:36 PM | benjamin | 02/07/2026 04:42 PM | ![]() |
FC-Adapter for SP100 and G100L Integrating Spheres | FC fibre adapter to allow fibre input to integrating spheres and free beam optical power meter detector heads. This adapter uses our proprietary design to eliminate back reflections into the detector which would otherwise result in miscalibration of the detector. The mounting holes are compatible with our P100, G100 and G100L integrating spheres. |
FC | • SP100 • G100L |
Buy |
| 12 | benjamin | 08/06/2026 01:37 PM | benjamin | 02/07/2026 04:44 PM | ![]() |
SMA-Adapter for SP100 and G100L Integrating Spheres | SMA fibre adapter to allow fibre input to integrating spheres and free beam optical power meter detector heads. This adapter uses our proprietary design to eliminate back reflections into the detector which would otherwise result in miscalibration of the detector. The mounting holes are compatible with our P100, G100 and G100L integrating spheres. |
SMA | • SP100 • G100L |
Buy |
Application Notes
You might also be interested in
Do you need further information? Find useful links here!
FAQs
What is the G100L integrating sphere?
The G100 is a 100 mm liquid-cooled gold integrating sphere by Artifex Engineering for measuring high power lasers up to 5 kW CW in the 650 nm – 20 µm range.
How much laser power can the G100L handle?
This gold sphere handles up to 5 kW continuous wave at a power density of up to 5 kW/cm². Exact limits for your configuration are stated in the documentation provided.
Why is the G100L liquid cooled?
At kilowatt power levels the sphere absorbs heat. Liquid cooling keeps the G100 thermally stable, enabling reliable measurements at power levels that convection-cooled spheres cannot handle.
What is the advantage of the G100L over a thermopile detector?
Thermopiles need around one second per measurement. This integrating sphere combined with a photodiode-based power meter resolves power fluctuations on a microsecond time scale.
Which power meters are compatible with the G100L?
This gold sphere connects via fibre coupling to Artifex OPM150 and OPM500 optical power meters.
Which fibre ports does the G100L offer?
It is available with SMA or FC fibre ports, in a standard 2-port design or with 4 ports on request.
What coating is used inside the Gold spheres?
This sphere uses a highly reflective diffuse gold coating optimized for the near and mid infrared.
Can the G100L be used for power and spectral measurement at the same time?
Yes. The multi-port design allows a power meter and a spectrometer to be connected simultaneously.
Is beam alignment critical with the G100?
No. Because the sphere diffuses incoming light, alignment into the 25 mm input port is generally not critical.
Do you offer calibration and recalibration for the G100L?
Yes. Artifex offers calibration and recommends periodic recalibration to maintain measurement accuracy.