Generic filters
Generic filters
Generic filters

THE Complete Solution

Artifex Engineering OPM150 is a low cost, versatile power monitor for the precise measurement of power, from nW to kW, for use in the lab and for OEM applications.

The Unit is USB powered and controlled.

A graphical user interface and a wide range of accessories make it as easy as possible to use this instrument.

Download OPM150 Broschure here – (pdf – 4MB)!

This product can be equipped with a variety of adapters and accessories for your specific application.

  • Interfaces: USB measurement rate: 1.5ms to 999s
  • Minimum measureable power: 1nW (photodiode)
  • Maximum measureable power: 12kW (Integrating sphere)
  • Gain control: 5 gain ranges
  • Functions: graph and digital display modes, averaging
Starting Single Unit Price: 426.66€

Low cost, versatile and small enough to fit into your pocket!

The OPM150 is a versatile power monitor for use in the lab and for laser servicing as well as for OEM applications. This laser measuring instrument is designed for use with a PC only, thus eliminating the need for a display. That makes this laser power meter very economical!

A very wide range of wavelength and powers. What would YOU like?

Various diode materials allow measurement from 250nm up to 2490nm.

Detectorheads are available covering 250-1000nm, 800-1550nm, 400-1600nm, 800-2000nm, 1000-2200nm and 1300-2490nm. Each head is automatically recognized and its individual calibration data are uploaded to the system.

Thus, changing wavelength range is as simple as swapping photodiode heads – all with one base unit.

We offer calibrated attenuation filters which extend the range of the free beam detector heads by up to three orders of magnitude. The user may load up to 5 separate filter curves to expand the dynamic range and functionality of the unit while ensuring proper calibration.

Calibrated integrating sphere heads compatible to the Artifex OPM150 power meter system round up the selection.

With a response time of 100µs and sampling rates up to 600S/s, there is much more to see than with a thermopile sensor. And no thermal drift to worry about either!

The Software – Integration made easy!

The graphical user interface is intuitive to use and easy to read. The software handles up to two optical light meter ssimultaneously and includes a scope function, data logging and a large, digital display – perfect for daily use in the lab or in the field. Further functions such as auto gain and various storage formats are also included.

This model is small enough to fit into your pocket and is a USB controlled power meter. No extra power supply required, no extra cables on the table.

Not only the small size qualifies this instrument as OEM optical power sensor for your applications. It is very simple and flexible to integrate into your project. The unit comes delivered with drivers for direct communication or to be used as a virtual COM-port. Furthermore, we provide a full software development kit including the source code for the GUI application as well as a demo LabView-VI.

Our philosophy: Make it as simple as possible to use this measuring instrument!

wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Order Code Description 30.070.00002 30.070.00058 30.070.00112 Units
1 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Application CW and pulsed source > 300kHz CW CW and pulsed source > 500Hz
2 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Input
3 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Max. Current 12 4 12 mA
4 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Output
5 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Connectors DB9 (detector head) and USB DB9 (detector head), BNC and USB DB9 (detector head) and USB
6 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Bandwidth 10 000 100 000 5 Hz
7 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Sampling Rate Standard modes
Fast sampling mode
30
600
30
600
30
600
S/s
8 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Gain Stages 1, 10, 100, 1000, 10000 1, 10, 100, 1000, 10000 1, 10, 100, 1000, 10000 V/mA
9 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Accuracy Detector ± 5 ± 5 ± 5 %
10 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Accuracy Base Unit ± 1 ± 1 ± 1 %
11 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Reproducibility Detector ± 1 ± 1 ± 1 %
12 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Linearity Detector ± 0.2 ± 0.2 ± 0.2 %
13 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Power supply
14 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Type USB USB USB
15 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Dimensions
16 benjamin 28/04/2026 10:15 AM benjamin 28/04/2026 10:15 AM Basemodule
Head
60 x 81 x 36 mm (W x L x H)
35 x 30 (Φ x L)
60 x 81 x 36 mm (W x L x H)
35 x 30 (Φ x L)
60 x 81 x 36 mm (W x L x H)
35 x 30 (Φ x L)
mm

Understanding Bandwidth and Pulse Measurement

When selecting an optical power meter, the bandwidth of the base module plays an important role in how rapidly changing optical signals are detected and interpreted. The bandwidth determines how quickly the internal transimpedance amplifier can respond to variations in optical power, which directly influences the suitability of the instrument for continuous wave (CW) sources or pulsed laser systems.

OPM150 Pulse

To illustrate this behavior, consider a laser source operating at a pulse repetition rate of 100 kHz with a pulse width of 10 µs. The optical signal changes far faster than the measurement bandwidth of the instrument. In this situation the optical power meter cannot resolve the individual pulses of the laser. Instead, the measurement represents a response to the overall signal rather than the detailed pulse structure.

OPM150 bandwith

100 kHz Measurement Unit
– Fast Optical Power Detection

The 100 kHz measurement unit provides the highest bandwidth available for the OPM optical power meter. This module is designed for applications requiring rapid optical power detection and fast response to signal changes.

When measuring high-frequency pulsed lasers, the detector can respond quickly enough to detect the presence of optical pulses, but the measurement may occur at any point within the pulse envelope. Because the measurement is not synchronized to the pulse timing, the recorded value can fall anywhere between the instantaneous peak power and the time-averaged optical power. For this reason, the highest-bandwidth configuration is typically recommended for continuous wave optical power measurement rather than precise pulse characterization.

OPM150 100kHz pulse

10 kHz Measurement Unit – Averaged Measurement of Modulated Sources

The 10 kHz measurement unit offers a slower response than the 100 kHz configuration but still allows the unit to follow relatively fast intensity changes. This makes it suitable for many modulated or partially pulsed optical sources where signal variations occur on moderate time scales.

When measuring very high repetition rate lasers, such as a 100 kHz pulse source with a pulse width of 10 µs, the detector bandwidth is not sufficient to resolve the individual pulse structure. Instead, the measurement electronics smooth the signal, producing an output that appears to be the average optical power delivered by the laser. In these situations, the detector behaves more like an averaging optical power meter rather than a pulse-resolved measurement device.

OPM150 10khz pulse

5 Hz Measurement Unit
– Stable Power Monitoring

The 5 Hz measurement unit is optimized for stable optical power monitoring where signal variations occur slowly over time. With a rise time of approximately 100 ms, the detector effectively integrates the incoming optical power over a relatively long time period.

Rapid fluctuations, such as those produced by high-frequency pulsed lasers, are averaged by the detector response and therefore do not appear in the output signal. Even significant variations within individual pulses have minimal influence on the measured value. This configuration is particularly well suited for continuous wave laser monitoring, optical alignment tasks, and long-term power stability measurements where a stable and noise-resistant measurement is required.

OPM150 5hz pulse

Sampling Rate vs Measurement Bandwidth

All these measurement units support a maximum sampling rate of 600 samples per second. The sampling rate determines how frequently measurement values are recorded and displayed in the software interface. For example, users may choose to log optical power data at 20 S/s for monitoring or data acquisition purposes.

It is important to distinguish this sampling rate from the internal measurement bandwidth of the detector electronics. The sampling rate controls how often measurements are recorded, while the bandwidth determines how quickly the optical power meter can respond to changes in the incoming optical signal. Selecting the appropriate measurement unit ensures that the bandwidth of the detector matches the dynamics of the laser source being measured.

OPM150 Complete System

Optical power meter with detector head and accessories as a flexible laser power meter for the lab!

Conveniently sorted in a small case there is:

  • an OPM150 Base Module
  • a free beam detector head (either Si or Ge)
  • an FC and SMA Fibre Adapter
  • two calibrated Attenuation Filters (OD1 and OD2)
  • USB cable
  • USB stick with software and documentation

You might also be interested in

Do you need further information? Find useful links here!

Software Development Kit

Artifex Software Development Kit

The SDK is a fixed, free component when purchasing a device.

It comes with the source code of the application program (in VB.net) and a LabView VI with the basic functions of the instrument. A description of the communication with the devices and a list of the commands used is also included.

FAQs

What is the OPM150 used for?

The OPM150 is an optical power meter that measures the output power of lasers, LEDs and other photonic devices. It is used in research labs, production testing, laser characterization, laser servicing and OEM systems.

What is a USB optical power meter?

A USB OPM measures optical power and uses a PC for power supply, control and display. The OPM150 needs only a USB cable, with no battery, power supply or built-in screen, which keeps cost and size low.

What wavelength range can the OPM150 measure?

This unit measures from 250 nm to 2490 nm, covering UV to short-wave infrared. The exact range depends on the detector head: 250–1000, 400–1600, 800–1550, 800–2000, 1000–2200 or 1300–2490 nm.

What optical power range can the OPM150 measure?

The OPM150 measures from 1 nW with a photodiode head up to 12 kW with an integrating sphere. Calibrated attenuation filters extend each free-beam head by up to three orders of magnitude.

How accurate is the OPM150?

Our detector heads are calibrated to ±5%, and the base module (amplifier) is specified at ±1%. Detector linearity is ±0.2% and reproducibility is ±1%.

Can the OPM150 measure pulsed lasers?

Yes, if the pulse duration is long relative to the detector bandwidth. For very short pulses, the power meter measures average power. The 5 Hz and 10 kHz units average pulsed sources, while the 100 kHz unit is recommended for CW sources.

Can the OPM150 measure white light sources?

No. This measuring instrument is a photodiode power meter, and photodiode responsivity depends strongly on wavelength. Only monochromatic sources such as lasers and single-colour LEDs can be measured accurately.

Why is a photodiode power meter faster than a thermopile?

A photodiode converts light directly into current, while a thermopile must heat up first. This OPM series responds in 100 µs, about 1000x faster than a thermopile laser power meter, and has no thermal drift.

Which measurement unit should I choose?

Choose 5 Hz for stable CW monitoring and alignment, 10 kHz for averaged measurement of modulated or pulsed sources, and 100 kHz for fast CW measurement. All units sample at up to 600 S/s.

Can I connect the OPM150 to a computer?

Yes. This unit is a USB optical power meter designed for PC operation. Its software provides live display, scope view, data logging and automated measurements, and it can run two units at once.

Can I integrate the OPM150 into my own system?

Yes. It ships with drivers for direct communication or use as a virtual COM port, a full SDK including the GUI source code, and a LabVIEW demo VI. It is often built into automated production test setups.

Which detectors are compatible with the OPM150?

Artifex Engineering photodiode detectors and integrating sphere detectors are compatible if they have a DB9 output or use a BNC-to-DB9 adapter compatible with Artifex devices. Each head is recognized automatically and loads its own calibration data.

Can I use an integrating sphere with the OPM150?

Yes. Calibrated integrating spheres measure the total emitted power of divergent sources such as LEDs and laser diodes, and they extend the OPM range up to 12 kW.

Can I measure fibre-coupled sources with the OPM?

Yes. FC and SMA fibre adapters are available for the Artifex free-beam detector heads.

Is the OPM150 suitable for production environments?

Yes. Its USB control, small size and SDK make this model easy to integrate into automated test stations.

How often does the OPM150 need calibration?

Artifex recommends recalibrating at least once every two years to maintain measurement accuracy.

What maintenance does the OPM150 require?

Maintenance is minimal: periodic calibration, connector inspection, and cleaning optical surfaces with clean, dry air only.

Do you offer customized OPM150 configurations?

Yes. Download the specification checklist from the Downloads tab and send it to our sales department with any additional requirements.

Donovan Ellis

Measuring Instruments

Donovan Ellis

Measuring Instruments